Beike supplies a comprehensive portfolio of Schneider Electric low-voltage switchgear and distribution equipment, engineered for safety, reliability, and energy efficiency. Our Schneider LV solutions — including BlokSeT 5000 and Prisma E systems — support modular configurations, intelligent monitoring (EcoStruxure-compatible), and tailored assemblies for industrial, commercial, and infrastructure projects worldwide.
Quick Highlights
Authorized Schneider Electric products and systems
Modular LV switchgear: withdrawable and fixed configurations
Rated current range: 630A – 5000A (model-dependent)
Compliance: IEC 61439, UL (optional models), GB/T standards
IP ratings available from IP31 to IP54 for indoor/outdoor use
On-demand customization, fast lead times, global delivery & support
Overview
Schneider low voltage switchgear from Beike provides integrated solutions for modern electrical distribution. Designed to meet demanding performance and safety requirements, these products are suitable for distribution boards, motor control centers (MCC), main distribution panels, and specialized power stations. With options for intelligent monitoring, energy management integration, and flexible enclosure designs, Schneider LV equipment is ideal for projects ranging from factory automation to data center power distribution and commercial building electrical infrastructure.
Featured Schneider LV Products
BlokSeT 5000 Low-Voltage Switchgear — A pre-intelligent, modular LV switchgear family suitable for high-current industrial applications. Highlights: high short-circuit withstand, modular busbar options, digital monitoring modules, withdrawable/fixed units.
2. Prisma E Distribution Equipment — Compact, flexible distribution system for commercial and infrastructure projects; optimized for simplified installation and integration with Schneider protection and metering components.
Product Features
Modular & Scalable Design
Standardized modular components (frames, drawers, busbar sections) allow straightforward expansion, on-site reconfiguration and cost-effective upgrades. Suitable for staged installations and future capacity growth.
High Protection & Safety
Advanced separation forms (compartmentalization), mechanical interlocks, door interlocks and IP-rated enclosures minimize risk of accidental contact and foreign object ingress. Arc-resistant options and arc flash mitigation measures are available.
Robust Electrical Performance
Wide range of rated currents and busbar systems (tinned or copper busbars), high short-circuit making/breaking capacity, and low-loss conductor designs ensure stable operation under heavy load and fault conditions.
Smart & Connected
Support for EcoStruxure (Schneider’s IoT/SCADA ecosystem), integrated digital meters, wireless temperature sensing, IoT gateways and remote diagnostics enable predictive maintenance and energy optimization.
Durability & Environmental Protection
Enclosure finishes (powder coat, epoxy) and materials (galvanized steel, stainless steel) provide corrosion resistance. Options for tropical, high-humidity, high-altitude and corrosive-environment designs.
Customization & Integration
Tailored busbar configurations, metering sections, capacitor banks, soft-starter and VFD integration, and layout/cable entry customization for site-specific requirements.
Technical Specifications
Rated operational voltage: up to 690V AC (typical LV systems)
Rated current per busbar system: 630A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A, 5000A (model dependent)
Short-circuit withstand capacity: up to 100kA (depending on model and busbar configuration)
Protection (ingress): IP31 to IP54 (depending on enclosures)
Insulation & impulse withstand: per IEC 61439 / manufacturer specs
Functional unit types: fixed, withdrawable (draw-out), plug-in, mixed arrangements
Separation forms: Type 1 / 2 / 3 / 4 (IEC separation forms, confirm per model)
Ambient operation: typically -25°C to +40°C; special versions for -40°C to +60°C or high-altitude available
Communication protocols: Modbus, IEC 61850 (optional for integrated systems), analog/digital I/O
Applications & Use Cases
Industrial Manufacturing & Plants — Main distribution, motor control centers (MCC), process lines, heavy equipment power.
Commercial Buildings & Complexes — Office towers, shopping centers, hotels — lighting and tenant distribution, energy monitoring.
Data Centers & IT Facilities — High-density power distribution, redundant feeds, critical loads with metering & remote monitoring.
Infrastructure & Utilities — Airport, station, water treatment, transportation systems requiring robust and maintainable LV distribution.
Renewable Energy Integration — PV plant inverters, battery energy storage system (BESS) integration, EV charging hubs.
Healthcare & Education — Hospitals and campuses where redundancy, monitoring and UL/IEC compliance are essential.
Why Choose Beike for Schneider LV Switchgear
Authorized Supplier & System Knowledge
Beike is experienced in deploying Schneider Electric LV systems and integrates Schneider components and architectures (e.g., EcoStruxure) into project-level solutions.
End-to-End Support
From initial technical consultation and system design to manufacturing, testing, site commissioning and long-term maintenance.
Customization & Fast Turnaround
Tailored assemblies, fast prototyping, and optimized lead times for project-critical deliveries.
Quality & Safety Compliance
Manufacturing under ISO quality processes, with products tested to IEC/UL/GB standards and optional third-party witnessing.
Global Delivery & Local Support
International shipping and local technical support for installation, commissioning and spare parts.
Manufacturing & Quality Assurance Process
1. Requirement & Consultation — Project scoping, site constraints, single-line diagram review, and spec confirmation.
2. Design & Engineering — Detailed electrical and mechanical design, BOM, 3D layout, and approval drawings.
3. Manufacturing — CNC fabrication, powder coating, component assembly, busbar welding and fabrication to tolerances.
4. Testing & Validation — Routine & type tests: insulation resistance, dielectric withstand, functional interlocks, secondary injection testing, temperature rise and short-circuit tests where applicable.
5. Delivery & Commissioning — Packaging for shipping, on-site installation support, SAT (Site Acceptance Testing), operator training and documentation handover.
Certifications & Standards
IEC 61439 series (Low-voltage switchgear and controlgear assemblies)
UL listings (models upon request / specific country variants)
ISO 9001 (Quality Management), ISO 14001 (Environmental), ISO 45001 / OHSAS (Health & Safety)
Regional compliance (GB/T in China, EN/European standards where applicable)
Optional compliance for utility specifications and EV/renewable projects (EUSERC / local utility requirements)
Customization Options & Typical Configurations
Enclosure Types: Indoor Type 1 / Outdoor Type 3R / IP54 housings / Stainless steel outdoor enclosures
Functional Sections: Main breaker, feeder breaker distribution, metering sections, capacitor banks, motor control centers, VFD/soft-starter bays
Busbar Materials & Configs: Copper or tin-plated copper, flat or C-profile busbars, multi-tier busbar systems
Protection & Controls: Electronic/microprocessor relays, MCCB, ACB, fuse combo units, LCD digital meters, energy analyzers
Communication: Modbus TCP, Modbus RTU, IEC 61850, BACnet (via gateways), cloud/IoT connectivity with EcoStruxure integration
Environmental Options: Tropicalized coatings, anti-corrosion treatments, high-altitude insulation adaptations, explosion-proof variants
Installation, Commissioning & After-Sales Service
Site survey and cable entry planning prior to delivery
On-site mechanical and electrical installation guidance
Pre-commissioning checks and SAT support
Operator training and Handover Documents (Schematic, BOM, Wiring Diagrams, Test Reports)
Long-term maintenance contracts, spare parts supply, firmware updates and remote diagnostics packages
Typical Project Timelines & Lead Times
Standard catalog assemblies: Typical lead time 4–8 weeks (subject to volume)
Custom engineered solutions: Lead time depends on design approval and testing — typically 6–12 weeks
Faster lead times available for critical projects with confirmed specifications and priority production slots
Case Studies
1. Factory Power Upgrade — Modular BlokSeT 5000 deployment replaced aging switchboards, increased short-circuit capacity and enabled online maintenance with withdrawable units.
2. Data Center Tier Upgrade — Prisma E distribution line provided compact footprint, integrated metering and EcoStruxure connectivity for remote monitoring.
3. Renewable Farm Interconnection — Customized LV switchgear integrated with inverter outputs and plant metering, enabling real-time energy reporting and power factor compensation.
Pricing Signals & Procurement Guidance
Provide clear request-for-quote (RFQ) instructions: required datasheet fields (single-line diagram, load summary, preferred enclosure, desired protections, site altitude, ambient conditions).
Offer downloadable datasheet & product brochure and model comparison tables.
Include indicative price ranges or ballpark estimates for common configurations (optional — useful for faster screening).
FAQs
Q: What is the typical rated current range for Schneider LV switchgear?
A: Models typically cover rated currents from 630A up to 5000A depending on the series (BlokSeT, Prisma, etc.) and busbar configuration.
Q: Do you offer UL-listed Schneider assemblies?
A: Certain assemblies and options can be supplied as UL-listed; please contact sales to confirm model-specific certifications.
Q: Can you integrate energy meters and remote monitoring?
A: Yes — Schneider LV systems integrate with EcoStruxure and support digital meters, communication gateways and SCADA/PLC integration.
Q: What are the main benefits of withdrawable vs fixed units?
A: Withdrawable (draw-out) units enable safe live maintenance and quick replacement, reducing downtime; fixed units are more compact and cost-effective for static installations.
Q: How do I request a custom switchgear quote?
A: Provide your single-line diagram, load summary, required protections, installation environment and desired delivery timeline via our contact form or RFQ template.