The Main Distribution Board (MDB) is a panel or enclosure designed to house fuses, circuit breakers, and residual current protection devices. It contains the necessary components to distribute electrical power to individual circuits or end-user points. Electrical power is supplied to the MDB from a transformer or an upstream distribution panel.
An MDB typically features one or more incoming power supplies and includes a main circuit breaker, residual current device (RCD) or earth leakage protection. It is composed of an independent enclosure, a busbar system, Molded Case Circuit Breakers (MCCBs), metering devices, auxiliary components, and corresponding current transformers. The internal layout follows a systematic configuration, clearly separating incoming and outgoing sections for safe and efficient power distribution.
The Main Distribution Board (MDB) serves as the central hub of your electrical infrastructure—the “nerve center” of power distribution. Engineered to handle currents of up to 6300A, our MDBs are designed for high breaking capacity systems, ensuring stable, uninterrupted power supply for demanding applications such as factories, high-rise buildings, and large commercial or industrial facilities.
BK Electric is a Main Distribution Board manufacturer and supplier providing low-voltage MDB panels for industrial, commercial and infrastructure projects. Installed downstream of transformers or generators, an MDB receives incoming power and distributes electricity to secondary distribution boards, production equipment and building electrical systems.
Our MDB panels support rated currents from 400A to 6300A, operating voltages of 400V/690V AC, and short-time withstand currents of 50–100kA/1s, depending on configuration. Each main distribution board can be designed with ACB or MCCB incoming protection, multiple outgoing feeders, copper or aluminum busbars, and optional metering and monitoring functions.
As an MDB panel manufacturer, BK Electric provides standard and customized configurations based on project drawings, electrical loads, short-circuit requirements and installation conditions. We also support component selection, engineering drawings, factory inspection and export documentation for international orders.
The following specifications outline the available MDB configurations. Final ratings depend on the selected circuit breakers, busbar system, enclosure structure and electrical design.
| Technical Parameter | Specification |
|---|---|
| Product Type | Main Distribution Board (MDB) |
| Rated Current | 400A–6300A |
| Rated Operational Voltage | 400V / 690V AC |
| Rated Frequency | 50Hz / 60Hz |
| Rated Insulation Voltage | 1000V AC |
| Rated Short-time Withstand Current (Icw) | 50–100kA / 1s |
| Rated Peak Withstand Current (Ipk) | 105–220kA |
| Rated Breaking Capacity | 65–150kA, depending on configuration |
| Protection Degree | IP31, IP41, IP42, IP54 (optional) |
| Enclosure Material | 2.0–3.0mm cold-rolled steel |
| Surface Treatment | Degreasing, phosphating and electrostatic epoxy powder coating |
| Standard Enclosure Color | RAL 7035 |
| Construction Type | Fixed, plug-in and withdrawable |
| Busbar Material | Copper or aluminum |
| Applicable Standards Listed | IEC 61439-1/-2, GB 7251.1, UL 508A |
Busbar Configuration
| Busbar Component | Configuration |
|---|---|
| Horizontal Busbar | Copper or aluminum |
| Vertical Busbar | Copper or aluminum |
| Neutral Busbar | Same size as phase busbar or reduced capacity |
| Earth Busbar | Independent earthing system |
Note: Short-time withstand current, peak withstand current and breaker breaking capacity are different electrical characteristics. Their final values must be verified against the selected assembly and protection components. Applicable standards and protection ratings are confirmed for each project.
BK Electric provides custom MDB manufacturing based on the electrical drawings and operating requirements of each project. The following configurations can be selected according to the required power distribution arrangement.
Main incoming protection using Air Circuit Breakers (ACB) or Molded Case Circuit Breakers (MCCB).
Multiple incoming power supply arrangements according to the electrical design.
Outgoing feeder quantity and breaker ratings based on connected loads.
Fixed, plug-in or withdrawable breaker arrangements.
Busbar sizing and layout according to rated current and short-circuit requirements.
Different internal separation forms can be selected according to electrical safety and maintenance requirements.
| Configuration | Available Options |
|---|---|
| Internal Separation | Form 2, Form 3, Form 4; exact subtype subject to design confirmation |
| Cabinet Construction | Fixed, plug-in, withdrawable or mixed configuration |
| Installation | Wall-mounted, free-standing or combined cabinet arrangement |
| Cable Entry | Top, bottom or side entry/exit |
| Enclosure Protection | IP31, IP41, IP42, IP54 |
| Cabinet Material | 2.0–3.0mm cold-rolled steel |
| Surface Finish | Electrostatic epoxy powder coating, standard RAL 7035 |
For projects requiring electrical measurement and centralized management, the MDB can incorporate:
Digital energy meters and multifunction power meters.
Current transformers (CTs) for electrical measurement.
Power quality monitoring instruments.
Remote monitoring and control functions.
Communication interfaces such as Modbus, Profibus and Ethernet, subject to compatible equipment.
Automatic Power Factor Correction (APFC) sections with capacitor banks.
BMS integration according to project communication requirements.
The main ACB, MCCB, metering instruments and auxiliary components can be selected according to project specifications and maintenance requirements.
Available component brand options include:
Schneider Electric
ABB
Siemens
Qualified Chinese electrical component brands according to project requirements
For a customized MDB quotation, please provide your Single Line Diagram (SLD), load schedule, required current rating, short-circuit level, preferred component brands and installation dimensions. Our engineering team can review the configuration and prepare the corresponding layout drawings and component list for approval.
As the main low-voltage power distribution point, an MDB supplies electricity from transformers or generators to downstream distribution systems and electrical equipment.
| Application | Typical Power Distribution Requirements |
|---|---|
| Industrial Manufacturing Plants | Production machinery, workshop equipment, auxiliary power and lighting circuits |
| High-Rise Buildings | Main electrical distribution, elevators, HVAC and public-area power |
| Hotels and Commercial Buildings | Guest rooms, kitchens, air conditioning and building services |
| Shopping Malls and Supermarkets | Retail units, lighting, refrigeration and central HVAC systems |
| Hospitals and Medical Facilities | General building power, utility systems and supporting electrical loads |
| Airports and Public Facilities | Terminal buildings, service areas and infrastructure equipment |
| Data Centers | Main power distribution, UPS-related distribution and auxiliary electrical systems |
| Water Treatment Plants | Pumping equipment, treatment machinery and facility power distribution |
The MDB configuration should be selected according to the total connected load, incoming power source, required feeder circuits, fault level and installation environment.
As an MDB manufacturer, BK Electric places emphasis on enclosure fabrication, electrical assembly and inspection before shipment. Inspection items are checked against the approved drawings, component list and applicable project requirements.
Check steel sheet thickness and enclosure dimensions.
Inspect cabinet fabrication, door alignment and structural assembly.
Check surface pretreatment and powder coating quality.
Verify the specified enclosure protection requirements.
Verify copper or aluminum busbar material against the approved BOM.
Check busbar dimensions, arrangement and connection points.
Inspect circuit breaker models, rated current and protection accessories.
Verify meters, current transformers and auxiliary components.
Check incoming and outgoing circuit wiring.
Verify cable connections, terminal identification and phase arrangement.
Inspect protective earthing and electrical connections.
Check breaker operation, mechanical interlocks and functional arrangements.
Before delivery, the MDB undergoes applicable factory inspection and routine testing, including:
Visual and assembly inspection.
Mechanical operation checks.
Electrical circuit continuity checks.
Insulation resistance testing.
Dielectric withstand testing according to the approved test plan.
Final inspection against approved technical drawings.
Design verification and type-test documentation should correspond to the applicable assembly system and project specification.
Factory Acceptance Testing (FAT) and third-party inspection can be arranged according to the agreed inspection requirements. Relevant inspection and test records can be supplied with the shipment.
Typical production lead time for standard configurations is:
Approximately 2–3 weeks after drawing confirmation and component availability.
For project-based customized systems, production schedules depend on:
Electrical configuration complexity
Component brand selection
Intelligent monitoring requirements
FAT / third-party inspection requirements
Typical lead time:
Approximately 4–6 weeks after technical approval.
Customization includes:
Non-standard dimensions
Special busbar layouts
Intelligent monitoring systems
Special IP protection requirements
Schneider / ABB component integration
To improve delivery speed, we maintain:
Standard cabinet body inventory
Semi-finished panel structures
Common breaker and busbar stock
This allows faster response for:
EPC urgent projects
Replacement orders
Fast-track infrastructure projects
We provide complete technical documentation for international projects.
General Arrangement Drawings (GA)
Single Line Diagram (SLD)
Wiring Diagrams
Bill of Materials (BOM)
Nameplate List
Before shipment, each MDB undergoes factory inspection and testing.
Documents provided include:
Routine Test Report
Factory Inspection Report
Insulation Resistance Test
Mechanical Operation Test Record
Optional:
Third-party inspection support
FAT (Factory Acceptance Test) witness service
To prepare an accurate quotation, please provide the Single Line Diagram (SLD), electrical load schedule, rated voltage, required current capacity, short-circuit level, number of incoming and outgoing circuits, preferred breaker brands and installation conditions. Cabinet dimensions and project quantity are also helpful.
Yes. BK Electric can review customer-provided SLDs and load schedules to determine the incoming and outgoing circuit arrangements, breaker selection, busbar configuration and cabinet layout. Engineering drawings and the component list can be submitted for approval before manufacturing.
Yes. The main ACBs, MCCBs and other electrical components can be selected according to the project specification. Schneider Electric, ABB and Siemens components are available as options, subject to model compatibility and procurement requirements.
Fixed configurations use permanently installed circuit breakers and are suitable for straightforward distribution arrangements. Plug-in configurations allow functional units to be connected through plug-in interfaces. Withdrawable configurations allow selected breaker units to be withdrawn for inspection or maintenance. The appropriate option depends on maintenance procedures, operational requirements and project budget.
Yes. MDB configurations can incorporate APFC capacitor banks, digital meters, power quality analyzers and compatible communication interfaces. BMS integration and remote monitoring functions should be specified during the engineering stage to confirm device and protocol compatibility.
The project documentation package can include General Arrangement (GA) drawings, SLDs, wiring diagrams, Bill of Materials (BOM), nameplate lists, factory inspection reports, routine test records and agreed FAT documentation. Third-party inspection can also be coordinated when specified in the purchase order.
The production schedule depends on cabinet quantity, electrical configuration, component selection, drawing approval and inspection requirements. The confirmed manufacturing lead time will be provided after technical specifications and the BOM are finalized.
MDB panels are divided into suitable shipping sections according to cabinet dimensions and transportation requirements. Export packaging can include moisture-barrier bags, desiccants, shock-absorbing protection and reinforced fumigation-free wooden crates to protect electrical components during international transportation.
Looking for a reliable MDB manufacturer and supplier for your industrial or commercial project?
BK Electric provides standard and customized Main Distribution Boards based on project electrical requirements, component preferences and installation conditions.
Send us your SLD, load schedule and technical specifications to receive an MDB configuration proposal and quotation.