Epoxy resin cast dry-type transformer is a high-performance dry-type transformer characterized by superior electrical strength, mechanical durability, and heat resistance. It is an excellent choice for urban power grid transformation projects.Manufactured using advanced production and testing equipment in accordance with stringent technological standards, this transformer offers high reliability and a long service life. Depending on the application environment, it can be equipped with various levels of protective shell or without a shell. This makes it suitable for a wide range of environments including high-rise buildings, commercial centers, hospitals,airports, subways, tunnels, densely populated residential areas,as well as special environments such as oil refineries, chemical plants, nuclear power plants, and nuclear submarines.


Details


Basic information

Type: Dry Type Transformer

Phase: Three

Service Voltage: 6kV-11KV

Rated Capacity: 30KVA~250OkVA

Vector group:Yyn0, Dyn11

Cooling type: ANAF

Core material: CRGO

Purpose:Three-phase dry type transformers are intended for transforming of electric energy in networks of power systems and in energy consumer networks.

Contact us now.png

Product Overview

Why Choose TY Transformer?

    Engineering support: Our technical team helps select the correct transformer for your load profile and environment.Project experience: Decades of experience delivering reliable distribution transformers for industrial and commercial projects.

    Flexible manufacturing: Small to medium volume production with the ability to customize per order.After-sales support: Documentation, spare parts and lifecycle services to keep your installation running smoothly.

 

Dry Type Electric Transformer Features:

    High voltage winding

    High voltage winding is with epoxy resin filled vacuum casting.which greatly reduces the partial discharge and improves the electrical strength of the coil. The inner and outer walls of the winding with glass fiber mesh plate filling, improves the impact toughness of the coil and the ability of resistance to sudden short circuit of the transformer. The coil is never dry crack.

    Low voltage winding

    The foil structure of the low-voltage winding solves the problem of radial helix angle when winding with wire, and makes the ampere-turns more balanced. At the same time,the coil uses radial cooling air pipe, which improves the heat defeat ability. The winding solid layer uses DMD epoxy resin prepreg, and the overall is dry solid forming.

    Iron core

    The iron core is made of high-quality cold-rolled silicon steel sheet, 45°full oblique joint structure; The core column is bound with F grade weftless adhesive tape, and the core surface is wrapped with epoxy resin, which reduces no-load loss, no-load current and iron core noise. Clamping parts and fasteners are treated with a unique surface to further improve the appearance quality of the product.

 

Dry Type Epoxy Resin Cast Power Transformer Advantage:

    Safe, fire-resistant, and environmentally friendly.

    Maintenance-free, easy installation, and low overall operating costs.

    Excellent moisture-proof performance, allowing normal operation at 100% humidity and immediate operation after shutdown without pre-drying.

    Low losses, low partial discharge, low noise, and strong heat dissipation capability, enabling operation at 150% rated load under forced air cooling conditions.

    Equipped with a comprehensive temperature protection control system to ensure reliable transformer operation.

    High reliability, as demonstrated by operational studies showing that the products have achieved international advanced reliability standards.

 

Dry power Transformer Applicable Environment:

    Altitude: ≤1000 meters.

    . Ambient temperature: Maximum +45°C, Minimum -30°C.

    . Relative humidity: ≤90% (+25 °C).

    . Max Ground ramp degree: ≤3°.

    . Seismic level: ≤0.3m/s2 at horizontal direction and≤0.15m/s2at vertical direction.

    . Installation environment: No obvious and heavy pollution, no explosive and corrosive gas and dust, with good air ventilation and no severe vibration and shock.

    . If the application environment is different from the above standard conditions, please contact for customized designs.

 

Dry Type Vacuum Cast Resin Transformer Standard Fittings:

    Terminal Connectors

    Cast resin coils

    Epoxy Resin Capacitive Insulator 

    Special Termination Arrangement

    Cable Box/Bus Duct

    Cooling Fan

    Rollers (Uni-Directional /Bi-Directional) Protection with Temperature Scanner

    Scanner Off Circuit Tap Changer

 

Typical Specifications

    Rating (kVA): 50 -1000 (custom sizes available)

    Voltage class: Low voltage distribution (up to 600 V class)

    Phases: Three-phase (single-phase available for small requirements)

    Winding material: Copper or Aluminum

    Temperature rise options: 80°C /115°C /150°C (selectable) 

    Insulation class: Class H (or per project requirement)

    Cooling: Air-cooled, natural convection (AN) - optional forced ventilation for higher ratings

    Protection: IP rating and terminal box options per site requirements

    Efficiency & losses: Engineered for competitive no-load and load loss performance

    Standards: Designed to meet IEC/EN and other regional electrical standards certifications available on request

 

 

Customization & Ordering

    We understand that every project is unique. TY Transformer offers tailored solutions including:

    Custom kVA and voltage configurations

    Special tap ranges and voltage regulation schedules

    K-Factor and harmonic-resistant designs for electronic loads

    Specialized enclosures, terminal blocks, and cabling arrangements

    Project documentation package: wiring diagrams, routine and type test reports, installation guidance

    To sped the quotation process, provide: required kVA primary and secondary voltages ambient conditions temperature, altitude, mounting preference (floor, pad, bench, indoor cabinet) and any special certifications or drawings required.

    Fast quote tip: including a short application note helps us recommend the optimal design and lead time.


FAQ

1. What are the primary applications for your Low Voltage Dry Type Transformers?

Our low voltage (LV) dry-type transformers are ideal for indoor power distribution where oil-filled units are restricted. They are widely used in data centers, commercial buildings, hospitals, and industrial plants to provide safe, reliable voltage transformation (e.g., 480V to 208V or 400V to 230V).

2. What insulation classes do you provide for LV transformers?

We primarily manufacture transformers with Class F (155°C) or Class H (180°C) insulation systems. These high-temperature ratings ensure that the transformer can handle continuous full-load operation and occasional overloads without degrading the winding insulation.

3. Why choose a "Dry-Type" over an oil-immersed transformer for LV applications?

Dry-type transformers are self-extinguishing and moisture-proof. They eliminate the risk of oil leaks and fire, making them much safer for indoor installations. Additionally, they are virtually maintenance-free, as there is no oil to test or replace.

4. What is the difference between VPI and Cast Resin insulation?

We offer two types of insulation technologies:

  • VPI (Vacuum Pressure Impregnation): Cost-effective, excellent for general indoor use.

  • Cast Resin: Windings are encapsulated in epoxy resin under a vacuum, providing superior protection against moisture, dust, and harsh industrial chemicals.

5. Do your transformers include electrostatic shielding?

Yes, upon request. We can integrate an electrostatic shield between the primary and secondary windings. This effectively suppresses high-frequency noise and transients, providing a "clean" power supply for sensitive electronic equipment and medical devices.

6. How do you handle heat dissipation in a dry-type design?

Our transformers utilize natural air cooling (AN) through optimized vertical cooling ducts between the windings. For higher power demands or confined spaces, we can equip the units with forced-air cooling (AF) fans to increase the continuous load capacity by up to 25-33%.

7. What Ingress Protection (IP) ratings are available for the enclosures?

Standard indoor enclosures are usually IP20 or IP23, which protect against solid objects and light water splashes while allowing for natural ventilation. For specialized industrial environments, we can customize the enclosure up to IP54 with filtered ventilation.

8. Are the windings made of Copper or Aluminum?

As a direct manufacturer, we offer both High-Purity Copper and Electrical-Grade Aluminum windings. Copper offers better conductivity and a smaller footprint, while Aluminum provides a more cost-effective solution with excellent thermal performance.

9. What testing standards do your transformers comply with?

Every transformer produced in our Shanxi factory is tested in accordance with IEC 60076-11 or IEEE C57.12.01. We conduct routine tests including:

Voltage ratio and vector group verification.

Insulation resistance and dielectric strength tests.

No-load and full-load loss verification.

10. How do you ensure the transformer is not damaged during international shipping?

We use export-standard reinforced plywood crates and moisture-proof vacuum packaging. The transformers are securely bolted to a heavy-duty wooden base to withstand the vibrations and impacts typical of long-distance sea or land freight.